shopblog.nl
Categorieën
  Sluiten

Meer Siemens
Meer Siemens in Schakelaars

3RV2131-4RA10 - Motor protection circuit-breaker 80A 3RV2131-4RA10

EAN: 4011209945531 - manufacturer-number: 3RV2131-4RA10 - Motor protection circuit-breaker 80A Overload release current setting 70 ... 80A, Adjustment range undelayed short-circuit release 1040 ... 1040A, Phase failure sensitive, Switch off technique Magnetic, Rated operating voltage 690 ... 690V, Rated permanent current Iu 80A, Rated operation pow...
301,76

Webshops met dit product

Webshop
Bezorging
Prijs

Anderen bekeken ook

GV3P80  - Motor protection circuit-breaker 80A GV3P80
GV3P80 - Motor protection circuit-breaker 80A GV3P80
EAN: 3606481304568 - manufacturer-number: GV3P80 - Motor protection circuit-breaker 80A Overload release current setting 70 ... 80A, Adjustment range undelayed short-circuit release 1120 ... 1120A, Phase failure sensitive, Switch off technique Thermomagnetic, Rated operating voltage 230 ... 690V, Rated permanent current Iu 80A, Rated operation power at AC-3, 230 V 22kW, Rated operation power at AC-3, 400 V 45kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Complete device in housing, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 50kA, Degree of protection (IP) IP20, Height 132mm, Width 55mm, Depth 136mm - GV3P80
306,19
NZMB1-M80  - Motor protection circuit-breaker 80A NZMB1-M80
NZMB1-M80 - Motor protection circuit-breaker 80A NZMB1-M80
EAN: 4015082657130 - manufacturer-number: NZMB1-M80 - Overload release current setting=63..80 A, Adjustment range undelayed short-circuit release=640..1120 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=440 V, Rated permanent current Iu=80 A, Rated operation power at AC-3, 230 V=22 kW, Rated operation power at AC-3, 400 V=45 kW, Type of electrical connection of main circuit=Other, Type of control element=Rocker lever, Device construction=Built-in device fixed built-in technique, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=25 kA, Degree of protection (IP)=IP20, Height=145 mm, Width=90 mm, Depth=88 mm - NZMB1-M80
296,81
GV4P80B6  - Motor protection circuit-breaker 80A GV4P80B6
GV4P80B6 - Motor protection circuit-breaker 80A GV4P80B6
EAN: 3606481310217 - manufacturer-number: GV4P80B6 - Motor protection circuit-breaker 80A Overload release current setting 40 ... 80A, Adjustment range undelayed short-circuit release 1360 ... 1360A, Phase failure sensitive, Switch off technique Electronic, Rated operating voltage 690 ... 690V, Rated permanent current Iu 80A, Rated operation power at AC-3, 400 V 37kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Complete device in housing, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 25kA, Degree of protection (IP) IP40, Height 155mm, Width 81mm, Depth 165mm - GV4P80B6
328,58
GV4PE80B  - Motor protection circuit-breaker 80A GV4PE80B
GV4PE80B - Motor protection circuit-breaker 80A GV4PE80B
EAN: 3606481310095 - manufacturer-number: GV4PE80B - Motor protection circuit-breaker 80A Overload release current setting 40 ... 80A, Adjustment range undelayed short-circuit release 1360 ... 1360A, Phase failure sensitive, Switch off technique Electronic, Rated operating voltage 690 ... 690V, Rated permanent current Iu 80A, Rated operation power at AC-3, 400 V 37kW, Type of electrical connection of main circuit Screw connection, Type of control element Rocker lever, Device construction Complete device in housing, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 25kA, Degree of protection (IP) IP40, Height 155mm, Width 81mm, Depth 116mm - GV4PE80B
301,76
GV4LE80S  - Motor protection circuit-breaker 80A GV4LE80S
GV4LE80S - Motor protection circuit-breaker 80A GV4LE80S
EAN: 3606481309976 - manufacturer-number: GV4LE80S - Motor protection circuit-breaker 80A Adjustment range undelayed short-circuit release 480 ... 1120A, Switch off technique Magnetic, Rated operating voltage 690 ... 690V, Rated permanent current Iu 80A, Rated operation power at AC-3, 400 V 37kW, Type of electrical connection of main circuit Screw connection, Type of control element Rocker lever, Device construction Complete device in housing, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 100kA, Degree of protection (IP) IP40, Height 155mm, Width 81mm, Depth 116mm - GV4LE80S
292,37
MM506N  - Motor protection circuit-breaker 1,6A MM506N
MM506N - Motor protection circuit-breaker 1,6A MM506N
EAN: 3250614435195 - manufacturer-number: MM506N - Motor protection circuit-breaker 1,6A Overload release current setting 1 ... 1,6A, Adjustment range undelayed short-circuit release 19,8 ... 29,8A, Phase failure sensitive, Switch off technique Thermomagnetic, Rated operating voltage 230 ... 690V, Rated permanent current Iu 1,6A, Rated operation power at AC-3, 230 V 0,25kW, Rated operation power at AC-3, 400 V 0,55kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Built-in device fixed built-in technique, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 150kA, Degree of protection (IP) IP20, Height 90mm, Width 45mm, Depth 70mm - MM506N
60,74
MM510N  - Motor protection circuit-breaker 10A MM510N
MM510N - Motor protection circuit-breaker 10A MM510N
EAN: 3250614435232 - manufacturer-number: MM510N - Motor protection circuit-breaker 10A Overload release current setting 6,3 ... 10A, Adjustment range undelayed short-circuit release 124 ... 186A, Phase failure sensitive, Switch off technique Thermomagnetic, Rated operating voltage 230 ... 690V, Rated permanent current Iu 10A, Rated operation power at AC-3, 230 V 2,2kW, Rated operation power at AC-3, 400 V 4kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Built-in device fixed built-in technique, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 150kA, Degree of protection (IP) IP20, Height 90mm, Width 45mm, Depth 70mm - MM510N
70,81
MM507N  - Motor protection circuit-breaker 2,5A MM507N
MM507N - Motor protection circuit-breaker 2,5A MM507N
EAN: 3250614435201 - manufacturer-number: MM507N - Motor protection circuit-breaker 2,5A Overload release current setting 1,6 ... 2,5A, Adjustment range undelayed short-circuit release 31 ... 46,5A, Phase failure sensitive, Switch off technique Thermomagnetic, Rated operating voltage 230 ... 690V, Rated permanent current Iu 2,5A, Rated operation power at AC-3, 230 V 0,37kW, Rated operation power at AC-3, 400 V 0,75kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Built-in device fixed built-in technique, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 150kA, Degree of protection (IP) IP20, Height 90mm, Width 45mm, Depth 70mm - MM507N
60,74
MM508N  - Motor protection circuit-breaker 4A MM508N
MM508N - Motor protection circuit-breaker 4A MM508N
EAN: 3250614435218 - manufacturer-number: MM508N - Motor protection circuit-breaker 4A Overload release current setting 2,5 ... 4A, Adjustment range undelayed short-circuit release 49,6 ... 74,4A, Phase failure sensitive, Switch off technique Thermomagnetic, Rated operating voltage 230 ... 690V, Rated permanent current Iu 4A, Rated operation power at AC-3, 230 V 0,75kW, Rated operation power at AC-3, 400 V 1,5kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Built-in device fixed built-in technique, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 150kA, Degree of protection (IP) IP20, Height 90mm, Width 45mm, Depth 70mm - MM508N
61,80
MM509N  - Motor protection circuit-breaker 6,3A MM509N
MM509N - Motor protection circuit-breaker 6,3A MM509N
EAN: 3250614435225 - manufacturer-number: MM509N - Motor protection circuit-breaker 6,3A Overload release current setting 4 ... 6,3A, Adjustment range undelayed short-circuit release 78,1 ... 117,2A, Phase failure sensitive, Switch off technique Thermomagnetic, Rated operating voltage 230 ... 690V, Rated permanent current Iu 6,3A, Rated operation power at AC-3, 230 V 1,1kW, Rated operation power at AC-3, 400 V 2,2kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Built-in device fixed built-in technique, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 150kA, Degree of protection (IP) IP20, Height 90mm, Width 45mm, Depth 70mm - MM509N
61,80

Klanten-reviews van 3RV2131-4RA10 - Motor protection circuit-breaker 80A 3RV2131-4RA10

Er zijn nog geen beoordelingen voor dit productBen jij de eerste die een review plaatst?

Meer over 3RV2131-4RA10 - Motor protection circuit-breaker 80A 3RV2131-4RA10

Productomschrijving

EAN: 4011209945531 - manufacturer-number: 3RV2131-4RA10 - Motor protection circuit-breaker 80A Overload release current setting 70 ... 80A, Adjustment range undelayed short-circuit release 1040 ... 1040A, Phase failure sensitive, Switch off technique Magnetic, Rated operating voltage 690 ... 690V, Rated permanent current Iu 80A, Rated operation power at AC-3, 230 V 22kW, Rated operation power at AC-3, 400 V 37kW, Type of electrical connection of main circuit Screw connection, Type of control element Turn button, Device construction Built-in device fixed built-in technique, Number of poles 3, Rated short-circuit breaking capacity lcu at 400 V, AC 65kA, Degree of protection (IP) IP20, Height 140mm, Width 75mm, Depth 97mm - 3RV2131-4RA10

Productspecificaties

Artikelnummer(s)
EAN
4011209945531
Brand
Siemens
Shopblog.nl maakt gebruik van cookies. Ga je verder op onze website, ga dan akkoord met het plaatsen van cookies en de verwerking van deze data door ons en vermelde partners.