EAN: 8011564131163 - manufacturer-number: DX59701 - Underground installation box as pull box or change of direction of cable protection pipes. Knockout knockouts for cable protection tubes from 50 to 110 mm are available on all sides. The bottom of the underground installation...
EAN: 8011564299238 - manufacturer-number: GW95327 - Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 2, Rated voltage 230V, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Voltage type AC, Frequency 50 Hz, Relea...
EAN: 8011564824256 - manufacturer-number: GWD4112 - Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 25A, Rated fault current 0,03A, Leakage current type A, Frequency 50 Hz, Width in number of modular spacings 4, Built-in depth 71,9mm - GWD4112
EAN: 8011564824294 - manufacturer-number: GWD4132 - Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 40A, Rated fault current 0,03A, Leakage current type A, Frequency 50 Hz, Width in number of modular spacings 4, Built-in depth 71,9mm - GWD4132
EAN: 8011564824317 - manufacturer-number: GWD4134 - Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 40A, Rated fault current 0,3A, Leakage current type A, Frequency 50 Hz, Width in number of modular spacings 4, Built-in depth 71,9mm - GWD4134
EAN: 8011564824348 - manufacturer-number: GWD4154 - Number of poles=4, Rated voltage=400 V, Rated current=63 A, Rated fault current=0,3 A, Leakage current type=A, Frequency=50 Hz, Width in number of modular spacings=4, Built-in depth=71,9 mm - GWD4154
EAN: 8011564214446 - manufacturer-number: GW94897 - Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 40A, Rated fault current 0,03A, Mounting method DIN rail, Leakage current type A, Short-circuit breaking capacity (Icw) 6kA, Frequency 50 Hz, D...
EAN: 8011564061194 - manufacturer-number: GW94367 - Earth leakage circuit breaker C16/0,03A Number of poles (total) 4, Number of protected poles 3, Rated current 16A, Rated fault current 0,03A, Frequency 50 Hz, Release characteristic C, Width in number of modular spacings 4 -...
EAN: 8011564058477 - manufacturer-number: GW92667 - Miniature circuit breaker 3-p C16A Release characteristic C, Number of poles (total) 3, Number of protected poles 3, Rated current 16A, Voltage type AC - GW92667
EAN: 8011564058491 - manufacturer-number: GW92669 - Miniature circuit breaker 3-p C25A Release characteristic C, Number of poles (total) 3, Number of protected poles 3, Rated current 25A, Voltage type AC - GW92669
EAN: 8011564299399 - manufacturer-number: GW95170 - Earth leakage circuit breaker B32/0,03A Number of poles (total) 4, Number of protected poles 4, Rated voltage 400V, Rated current 32A, Rated fault current 0,03A, Leakage current type A, Rated short-circuit breaking capacity a...
EAN: 8011564299221 - manufacturer-number: GW95326 - Earth leakage circuit breaker B10/0,03A Number of poles (total) 2, Number of protected poles 2, Rated voltage 230V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 10A, Rated fault cu...
GW43022S - Surface mounted distribution board 300mm GW43022S
EAN: 8011564279773 - manufacturer-number: GW43022S - Surface mounted distribution board 300mm Mounting method Surface mounted (plaster), Number of rows 2, Width in number of modular spacings 12, Type of cover Optional, Cover model With notch, Material housing Plastic, Height 3...
EAN: 8034035018787 - manufacturer-number: GWD4532 - Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 40A, Rated fault current 0,03A, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Mounting method DIN rail, Leakage c...
EAN: 8034035018800 - manufacturer-number: GWD4537 - Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 63A, Rated fault current 0,03A, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Mounting method DIN rail, Leakage c...
Gewiss GWD4012 GWD4012 Aardlekschakelaar 1-fasig A 2-polig 25 A 0.03 A 230 V
FI aardlekschakelaar als netzspannungsunabhaengiger aardlekschakelaar (RCCB) EN610 08-1. Geschikt voor het nachtraeglichen montage van 2 aanvullende voorzieningen en / of combinaties met modules voor...
Gewiss GW94897 GW94897 Aardlekschakelaar 3-fasig A 4-polig 40 A 0.03 A 400 V
Compacte FI aardlekschakelaar als netzspannungsunabhaengiger aardlekschakelaar (RCCB) conform EN610 08-1. Geschikt voor het nachtraeglichen aanbouw van 1 extra aansluiting of modules voor automatische...
Vormdeel voor broedingskanaal als buiten- of binnenhoek; platte hoek; eindstuk; of T-stuk. Als kapdelen kunt u de snijranden van de canaele en de gewassen randen zo netjes afmaken.De teksten...